... and all other continents |
|
|
| HOME | ABOUT US | CONTACT DETAILS | E-MAIL | INQUIRY FORM | WHAT'S NEW | PRODUCTS & SERVICES | PROCUREMENT SERVICE | | ||
|
VOLTAGE STABILIZERS | ||
| SUPERVOLT Ferro Resonant Line Conditioner |
150VA - 20KVA Single Phase | |
| Line
Conditioning or Constant Voltage Transformers (CVT) are the next best solution to online UPS systems if total
protection from mains failure is not required. These units provide total
galvanic isolation between supply and load. They allow earthing of the
secondary neutral, thus providing complete isolation against voltage
drops, surges, spikes
and electrical noise. They also offer protection against lightning.
Applications:
|
|
MODELS
|
MODEL |
INPUT//OUTPUT |
RATING |
CURRENT |
SIZE in mm H x W x D |
WEIGHT |
|
SC150S |
230//230 V |
120 W |
0.52 A |
206 x 392 x 282 |
17 kg |
|
SC250S |
230//230 V |
200 W |
0.87 A |
206 x 392 x 282 |
18 kg |
|
SC500S |
230//230 V |
400 W |
1.74 A |
206 x 392 x 282 |
21 kg |
|
SC750S |
230//230 V |
600 W |
2.61 A |
206 x 392 x 282 |
24 kg |
|
SC1000S |
230//230 V |
800 W |
3.48 A |
206 x 392 x 282 |
25 kg |
|
SC1500S |
230//230 V |
1.2 k W |
5.22 A |
206 x 392 x 282 |
36 kg |
|
SC2000S |
230//230 V |
1.6 k W |
7.27 A |
263 x 400 x 550 |
55 kg |
|
SC2500S |
230//230 V |
2.0 k W |
9.09 A |
263 x 400 x 555 |
59 kg |
|
SC3000S |
230//230 V |
2.4 k W |
10.91 A |
263 x 400 x 565 |
65 kg |
|
SC4000S |
230//230 V |
3.2 k W |
14.55 A |
263 x 400 x 600 |
83 kg |
|
SC5000S |
230//230 V |
4.0 k W |
16.18 A |
263 x 400 x 630 |
90 kg |
|
SC6000S |
230//230 V |
4.8 k W |
21.82 A |
380 x 375 x 890 |
154 kg |
|
SC7500S |
230//230 V |
6.0 k W |
27.27 A |
380 x 375 x 920 |
172 kg |
|
SC10000S |
230//230 V |
9.0 k W |
36.36 A |
380 x 375 x 970 |
212 kg |
|
SC12000S |
230//230 V |
9.6 k W |
43.64 A |
600 x 800 x 450 |
290 kg |
|
SC15000S |
230//230 V |
12 k W |
54.55 A |
800 x 800 x 450 |
340 kg |
|
SC18000S |
230//230 V |
14 k W |
65.45 A |
800 x 1100 x 450 |
435 kg |
|
SC20000S |
230//230 V |
16 k W |
72.73 A |
800 x 1100 x 450 |
450 kg |
TECHNICAL SPECIFICATIONS FOR SINGLE PHASE CVT
| Input Voltage | Single phase 230 V (184 - 276). Other voltages available on request | |
| Supply Frequency | 50 Hz | |
| Output Voltage | 230 V. Other voltages available on request | |
| Output Accuracy | Better than 3% (1% option available) | |
| Harmonic Distortion | Typically less than 2% | |
| Effect of frequency change | 1% change in frequency produces approximately 5% change in output voltage | |
| Response | Typically 1 - 2 cycles (20 - 40 milliseconds) | |
| Ratings | See table above | |
| Overload | Short circuit limited | |
| Efficiency | Approximately 85% at full load | |
| Noise Attenuation | Symmetrical-mode (Transverse-mode)
60 dB Typ. (150 KHz - 10 MHz) Asymmetrical-mode (Common-mode) 60 dB Typ. (150 KHz - 10 Mhz) | |
| EMI / RFI Suppression | Yes | |
| Load Factor | 0.8 | |
| Operation Temperature | 0 Deg C - 40 Deg C | |
| Construction | Powder coated metal enclosure | |
| Connections | Input / output plug and socket up to 4000VA. Hardwire connection on request | |
| Standards | IEC 1000-4/4 or EN 61000-4-4 (Burst) IEC 1000-4/5 or EN 61000-4-5 (Surge) |
ISPRII or EN 55011 CE marked |
| Warranty | 1 Year | |
For more power related products
Please visit the WebSite of our sister company A & P Logistics
Suppliers of Renewable Energy and associated Products
Inverters * Power Backup Systems * PV Modules * Solar Lighting
Solar Water Pumping Systems * Wind Turbines * Batteries
Importers and export suppliers of specialized electronic and electrical equipment
Home | E-mail
|
Contact
Details | Products & Services | Previous Page |
Next
Page
Copyright © 200
3-2006 AMOS Technology & Projects CC. All rights reserved.